This is an old revision of the document!
P0139/P0145/P0159/P0165 O2 Sensor Circuit Slow Response
If using an
iO2SS in either automatic (signal augmentation) mode or manual (signal generation) mode, simply adjust the potentiometer to increase the period of the signal and eliminate this error code.
Return to iO2SS Page